SURFTEST SJ-310 SERIES

PORTABLE SURFACE ROUGHNESS TESTER

F

O

R

M

M

E

A

S

U

R

E

M

E

N

T

Bulletin No. 2141(2)

The Surftest SJ-310 is a compact, portable, easy-to-use surface

roughness measurement instrument equipped with extensive

measurement and analysis features.

Easy to use

Large color graphic LCD

The color touch-screen provides excellent

readability and an intuitive display that is easy

to negotiate. The LCD also includes a backlight

for improved visibility in dark environments.

The integrated printer allows you to print

measurement results on the spot.

Enhanced power for making measurements on site

Despite its reduced charging time — approximately 1/4 that required for conventional

models, the Surftest SJ-310 is capable of making approximately 2.5 times the number

of measurements when fully charged. The detector supports a variety of measurement

orientations and can make measurements up against a wall surface or while facing upward.

When combined with optional accessories such as a height gauge adapter, the detector can

make measurements in various orientations and settings.

Highly functional

Internal memory

Up to 10 measurement conditions and one measured

profile can be stored in the internal memory.

Optional memory card

The optional memory card can be used as an

extended memory to store large quantities of

measured profiles and conditions and adds the

convenience of automatically saving data from

the 10 most recent measurements (Trace 10).

Password protection

Access to each feature can be password-protected,

which prevents unintended operations and allows

protection of your settings.

Multilingual support

The display interface supports 16 languages, which

can be freely switched.

Stylus alarm

(patent pending in Japan, U.S.A., EU)

An alarm warns you when the cumulative

measurement distance exceeds a preset limit.

Extensive analysis and display features

Complies with many industry standards

The Surftest SJ-310 complies with the following

standards: JIS (JIS-B0601-2001, JIS-B0601-1994, JIS

B0601-1982), VDA, ISO-1997, and ANSI.

Displays assessed profiles and graphical data

In addition to calculation results, the Surftest SJ-310

can display sectional calculation results and assessed

profiles, load curves, and amplitude distribution curves.

2

User friendly, high-functionality display unit with integrated high-speed printer

The large 5.7-inch color graphic touch-screen LCD provides excellent readability. Furthermore, selecting icons from the touch panel display*

1

provides intuitive and easy operation. The integrated high-speed printer also allows the user to perform the entire process from making

measurements to printing the results with the push of a single button (START button).

*1 Text display can also be selected.

Printer5.7-inch color graphic LCD

with touch screen

BAC and ADC curves can be printed in addition

to calculation results (including pass/fail results)

and assessed profiles. The printer offers an

easy-to-understand layout and can also print

horizontally to match the content displayed on the

LCD. Furthermore, printing speed is approximately

50% faster than conventional models.

Built-in battery

With drastically enhanced power compared

to conventional models, the Surftest SJ-310

can make 1,500 continuous measurements

on a full charge achieved in 4 hours.

Key-sheet buttons

Measurement Result

Measured profile

One-touch

switching

←→

BAC curve

ADC curve

Frequently used functions, such as the measurement start button,

are provided as rugged sheet buttons with excellent durability.

Highly functional detectors and drive units

Detector supplied

as standard

A wide range of optional detectors

is available, including detectors for

small holes, extra small holes, gear

tooth surfaces, and deep grooves.

Drive units

Standard drive unit

• Popular standard drive unit

Transverse tracing drive unit

Retractable drive unit

• Best suited for measurement

of narrow, shrouded workpiece

features such as crankshaft

bearings, EDM parts, etc.

(Patent Registered in Japan)

One of two types may be selected:

• The detector is in the retracted

position at rest so it is immune

from damage when inserted into

a feature whose shape cannot be

easily seen, such as a blind hole, etc.

Measuring force: 0.75mN

Stylus form: Tip radius 2µm

Tip angle 60°

Measuring force: 4mN

Stylus form: Tip radius 5µm

Tip angle 90°

Links to a wide variety of external instruments

You can save parameter recalculations and measurement results in text format on a memory card and import into commercial spreadsheet software

on a PC. You can also connect to a PC using the USB connector and use a dedicated software application to

perform everything from measurement control and condition modification to issuing inspection result reports.

PC

Memory card

(Option)

Side of display unit

U-WAVE-T *

2

USB I/F

RS-232C I/F

SPC I/F

USB Input Tool

Direct *

2

Input Tool

for USB *

2

U-WAVE-R *

2

Rear of display unit

DP-1VR *

2

*2: Refer to P11 for more details

3

Measurement assistance and analysis features

offering the ultimate in ease of use

Switches between icon and text display

The display can be switched between icon and text, providing easy, user-friendly operation.

Additionally, the guidance feature provides detailed explanations of touch-screen buttons.

IconText

Easy specification of assessment conditions from a list

Setting assessment conditions is simple because you can select the desired condition from a displayed list (e.g., standard, parameter).

Zooming waveforms and analyzing coordinate differences

You can not only

magnify or shrink

waveforms, but also

calculate the coordinate

difference between

two points using a ruler

operation.

You can quickly check

the irregularity status

without waiting for a

printout.

Deleting unnecessary data

With the Surftest

SJ-310, you can

delete portions of

measurement data.

This feature allows

you to make new

calculations by deleting

data that should not be

included in parameter

calculation, such as

data on a scratch.

Displaying pass/fail results

By specifying a tolerance in advance, you can display pass/fail results in color.

Surface texture symbol entry

You can enter assessment conditions using

ISO/JIS surface texture symbols.

(Patent registered in Japan, U.S.A., Germany, UK, France)

(Patent pending in China)

OK+NG-NG

4

Measurement results can be displayed in several ways

Measurement results can be presented in the form of a 1-parameter, profile, 4-parameter or trace display.

1-parameter display: one parameter

measurement result

Profile display: one parameter measurement

result and the measured profile

4-parameter display: four parameter

measurement results

Trace display: the ten latest measurement

results using the same parameter

Recalculation function

After completing measurement, you can modify the assessment conditions (standard, profile, and parameter) and easily recalculate the results using

the new condition.* *

Not possible with all measurement conditions.

Dual assessment of a single measurement

Using the result of a single measurement, you can make calculations or

analyze assessment profiles under two different assessment conditions

(standard, profile, filter, etc.) without using the recalculation feature.

Stylus alarm function

Displayed settings can be easily changed by pressing the left and right

arrow keys under the sliding cover. For example, these keys can be used

to switch the cut-off value(λc) and the number of sampling lengths (N)

on the measurement screen. (Patent pending in Japan.)

Positive stylus contact indication

Stylus contact with the workpiece is indicated by color coding

in the display. This is helpful when visibility of the surface to be

measured is restricted (e.g. when measuring within a shrouded

feature or groove).

Extensive statistical processing features

You can make a maximum of 300 statistical measurements using up to three

parameters to obtain averages, standard deviations, maximums, minimums,

passing rates, and histograms (upper and lower limits can be displayed).

This feature is ideal for day-to-day data management.

No contact Contact

5

Specifications

Specifications

Type of detector

Model No.

Order No.

X axis

inch/mm

Range

Range/

resolution

Standard drive unit typeRetractable drive unit typeTransverse tracing drive unit

SJ-310SJ-310SJ-310SJ-310SJ-310SJ-310

(0.75mN type)(4mN type)(0.75mN type)(4mN type)(0.75mN type)(4mN type)

178-571-01A178-571-02A178-573-01A178-573-02A178-575-01A178-575-02A

.7"(17.5 mm) .22"(5.6 mm)

14400 µinch (-7900 µinch to +6300 µinch) [360 µm (-200 µm ~ +160 µm)]

14400 µinch / .8 µinch (360 µm / 0.02 µm)

4000 µinch / .2 µinch (100 µm / 0.006 µm)

1000 µinch / .08 µinch (25 µm / 0.002 µm)

In the measurement: .01inch/s (0.25mm/s), .02inch/s (0.5mm/s), .03inch/s (0.75mm/s), In the return: .04inch/s (1mm/s)

0.75mN type: 0.75mN / 2µmR 60°, 4mN type: 4mN / 5µmR 90°

400mN or less

JIS’82 / JIS’94 / JIS’01 / ISO’97 / ANSI / VDA / FREE

Primary(P), Roughness(R), DF, R-Motif, W-Motif

Ra, Rc, Ry, Rz, Rq, Rt, Rmax*

1

, Rp, Rv, R3z, Rsk, Rku, Rc, RPc, Rsm, Rz1max*

2

, S, HSC, RzJIS*

3

, Rppi, R

a, R

q, Rlr, Rmr,

Rmr

(

c

)

, Rδc, Rk, Rpk, Rvk, Mr1, Mr2, A1, A2, Vo, λa, λq, L

0

, Rpm, tp*

4

, Htp*

4

, R, Rx, AR, W, AW, Wx, Wte, Possible Customize

BAC and ADC curves

Gaussian, 2CR75, PC75

.003, .01, .03, .1, .3" (0.08, 0.25, 0.8, 2.5, 8 mm)

100, 320 µinch (2.5, 8 µm)

.003, .01, .03, .1, .3" (0.08, 0.25, 0.8, 2.5, 8 mm)

×1, ×2, ×3, ×4, ×5, ×6, ×7, ×8, ×9, ×10,

×1, ×2, ×3, ×4, ×5, ×6, ×7, ×8, ×9, ×10, Arbitrary

Arbitrary .0118 ~ .22"(.0001" Interval)

.0118 ~ .6299"(.0001" Interval) [(0.3 ~ 16.0mm: 0.01mm Interval)]

[(0.3 ~ 5.6mm: 0.01mm Interval)]

4.64" x 3.47" (117.8 × 88.2 mm)

Japanese, English, German, French, Italian, Spanish, Portuguese, Korean,

Traditional Chinese, Simplified Chinese, Czech, Polish, Hungarian Turkish, Swedish, Dutch

1-parameter display: one parameter measurement result

4-parameter display: four parameter measurement results

Profile display: one parameter measurement result and the measured profile

Trace display: The ten latest measurement results using the same parameter

Measurement conditions / Calculation results / GO / NG judgement result / Calculation results for each sampling length /

Measurement curve / BAC / ADC / Environmental setting information

USB I/F, Digimatic output, RS-232C I/F, External SW I/F

Desired parameters can be selected for calculation and display

Max rule / 16% rule / Average rule / Standard deviation (1

σ

, 2

σ

, 3

σ

)

Save the condition at power OFF

Internal memory: Measurement condition (10 sets)

Memory card (option): 500 measurement conditions, 1000 measuring data, 10000 text data, 500 statistic data,

500 image data, 1 backup of machine setting, the last ten traces (Trace 10)

Saves last inputted nominal value of specimen / Average calibration with multiple measurement (MAX.12 times) is available

Auto-sleep function (30-600sec) *

7

Two-way power supply: battery (rechargeable Ni-MH battery) and AC adapter

*Charging time: about 4 hours (may vary due to ambient temperature)

*Endurance: about 1500 measurements (differs slightly due to use conditions / environment)

10.8"x 4.3" x 7.8"(275 × 109 × 198 mm)

4.5"x 0.9" x 8.9"(115 × 23 × 26.7 mm)

About 1.8kg (Display unit + Drive unit + Standard detector)

12AAM475

12AAA217

12AAA218

12AAA216

12BAK700

12BAG834

12BAL402

270732

12BAL400

178-602

357651

02ZAA010

Connecting cable *

8

Nosepiece for plane surface

Nosepiece for cylinder

Supporting leg

Calibration stage

Stylus pen

Protection sheet

Printer paper (5 pieces)

Carrying case

Roughness reference specimen (Ra 119µin/3µm)

AC Adapter

Power Cord set (UL/CSA)

12AAM475

12AAE643

12AAE644

12BAK700

12BAG834

12BAL402

270732

12BAL400

178-606

357651

02ZAA010

Connecting cable *

8

Point-contact adapter

V-type adapter

Calibration stage

Stylus pen

Protection sheet

Printer paper (5 pieces)

Carrying case

Roughness Reference Specimen

(Ra 0.039µin/1.0µm)

AC Adapter

Power Cord set (UL/CSA)

Measuring

range

Detector

Measuring speed

Measuring force / Stylus tip

Skid force

Standard

Measured profiles

Parameters

Graph analysis

Filter

Cut-off length

Sampling length

λ

c

λ

s *

5

Number of sampling lengths

LCD dimensions

Display languages

Measurement result display

Printing function

External I/O

Customization

GO/ NG judgement *

6

Storage of measurement

condition

Storage

Calibration

Power-saving

Power supply

Size (W×D×H)

Mass

Display unit

Drive unit

Functions

Standard accessories

Philips screwdriver, Strap for stylus pen, Operation manual, Quick reference manual, Warranty

*1: Only for VDA/ANSI/JIS’82 standards.

*2: Only for JIS’97 standard.

*3: Only for JIS’01 standard.

*4: Only for ANSI standard.

*5:

λ

s may not be switchable depending on a standard selected.

*6: Standard deviation only can be selected in ANSI.16% rule cannot be selected in VDA.

*7: Auto-sleep function is invalid when AC adapter is used.

*8: For connecting the calculation display unit and drive unit.

6

Dimensions: Display Unit and Drive Unit

Drive unit, Display unit

Drive unit type

0

.

9

1

(

2

3

.

0

)

Unit: inch(mm)

Drive unit external view

Standard drive unit

1

.

0

2

(

2

6

.

0

)

0.99”(25.2)

1.05”(26.7)4.53”(115.0)

0.08”(2.0)

0.91”(23.2)

1.05”(26.7)

4.53”(115.0)

Transverse tracing drive unit

0.118”(3.0)

0.26”(6.6)

1

.

0

2

(

2

6

.

0

)

0

.

9

1

(

2

3

.

0

)

.

0

3

9

(

1

)

1.8”(45.5)

1.85”(47)4.53”(115.0)

Retractable drive unit

Display unit external view

Cable length: 1m

1

.

0

2

(

2

6

.

0

)

0

.

9

1

(

2

3

.

0

)

10.83”(275)

4.29”(109)

7

.

8

(

1

9

8

)

1

5

°

7

Dimensions: Detectors

Detectors

Standard detectors

16.4

6

3.5

61

Stylus

ф

9

ф

2

Unit: mm

Gear-tooth surface detectors

R

4

0

0

.

9

12.6

6

0

°

0

.

4

1

.

8

60.1

Stylus

2

.

4

4.8

1.5

59.5

0.6

1.4

Stylus

Order No.

Measuring

force form*

178-2960.75mN 2 µmR/60˚

178-3904 mN 5 µmR/90˚

178-3870.75mN 2 µmR/60˚

178-3864 mN 5 µmR/90˚

178-3950.75mN 2 µmR/90˚

178-3914 mN10 µmR/90˚

*Tip radius / Tip angle

Remarks

Dedicated to the

standard/retractable

drive unit

Dedicated to the

transverse tracing

drive unit

Dedicated to the

standard/retractable

drive unit

Order No.

178-388

178-398

Measuring

force

0.75mN

4 mN

Stylus form*

2 µmR/60˚

5 µmR/60˚

*Tip radius / Tip angle

Small hole detectors

ф

Deep groove detectors

3

.

8

16.2

60.7

Stylus

3.5

9

1

3

.

6

16.4

61

Stylus

ф

9

ф

9

1.5

2

1.5

4.8

Stylus

Order No.

Measuring

Remarks

force form*

178-3830.75mN2 µmR/60˚

Minimum

measurable hole

178-3924 mN5 µmR/90˚

diameter:

ø

4.5mm

*Tip radius / Tip angle

Stylus

Order No.

Measuring

Remarks

force form*

178-3850.75mN2 µmR/60˚

Not available for the

transverse tracing

178-3944 mN5 µmR/90˚

drive unit

*Tip radius / Tip angle

Extra small hole detectors

ф

2

.

4

12.8

60.3

Stylus

ф

9

0

.

4

0.8

*Tip radius / Tip angle

Stylus

Order No.

Measuring

Remarks

force form*

178-3840.75mN2 µmR/60˚

Minimum

measurable hole

178-3934 mN5 µmR/90˚

diameter: ø2.8mm

8

1

.

8

1.6

1

0

3.5

4.8

ф

9

.

4

Dimensions: Display Unit and Drive Unit

Drive unit, Display unit

Nosepiece for flat surfaces

No.12AAA217

• SJ-310/310R standard accessories

• Not available for the transverse

tracing drive unit.

Nosepiece for flat surface

No.12AAA217

Nosepiece for cylindrical surfaces

No.12AAA218

• SJ-310/310R standard accessories

• Not available for the transverse

tracing drive unit.

• ø30mm or smaller workpiece.

Nosepiece for

cylindrical surface

No.12AAA218

V-type adapter

No.12AAE644

• SJ-310S standard accessories

• Dedicated to the transverse tracing

drive unit.

7.7mm

7

2

m

m

Point-contact adapter

No.12AAE643

• SJ-310S standard accessories

• Dedicated to the transverse

tracing drive unit.

Extension rod (50 mm)

No.12AAA210

• Not available for the transverse

tracing drive unit.

Extension rod 50 mm

No.12AAA210

Extension cable (1 m)

No.12BAA303

• For connecting calculation display unit and drive unit.

Support feet set

No.12AAA216

• SJ-310 standard

accessory

• Not attachable to

the detector side

of the transverse

tracing drive unit.

Support feet set

No.12AAA216

Vertical positioning adapter

No.12AAA219

• Not available for the

transverse tracing drive unit

Detector side

Vertical positioning

adapter

No.12AAA219

Magnetic stand adapter

No.12AAA221(ø8mm)

No.12AAA220(ø9.5mm)

Magnetic stand

adapter

Height gage adapter

No.12AAA222(9x9mm)

No.12AAA233(1/4inx1/2in)

Height gage adapter

Setting attachments

(Note: Not available for the transverse tracing drive unit)

Enhances measurement efficiency by facilitating the measurement setup of multiple workpieces of the same type and of the hard-to-access

sections of a workpiece.

V-type for measuring axially

No.178-033

The V-width is adjustable

to the cylindrical workpiece

diameter, facilitating axial

measurement of a wide

range workpiece sizes.

• Adjustable range:

ø 5 ~ 150 mm

Slider type

No.178-034

This attachment is ideal for measuring

a flat area of a workpiece that has

an indentation or step that makes it

difficult to attach the drive unit. You

can further improve the ease of use

by using this attachment with the

magnetic installation base (option:

No. 12AAA910).

Inside diameter type

No.178-035

Greatly facilitates measurement

of internal wall surfaces of, for

example, a cylinder block.

• Applicable diameter:

ø 75 ~ ø 95 mm

• Accessible depth:

30 ~ 135 mm

9

Optional Accessories: For External Output

Simplified communication program for SURFTEST SJ series

The Surftest SJ-310 series has a USB interface, enabling data to be transferred to a spreadsheet or other software.

We also provide a program that lets you create inspection record tables using a Microsoft Excel* macro.

Required environment*:

• OS:

• Spreadsheet software:

Windows XP-SP3

Microsoft Excel 2000/2002/

Windows Vista

2003/2007/2010/2013/2016

Windows 7/8/10

*Windows OS and Microsoft Excel are products of

Microsoft Corporation.

Required environment*:

• USB cable for SJ-310 series

No. 12AAD510

This program can be downloaded free of charge from

the Mitutoyo website.

Contour / Roughness analysis software FORMTRACEPAK

More advanced analysis can be performed by loading SJ-310 series measurement data to software program FORMTRACEPAK

via a memory card (option) for processing back at base.

10

Optional Accessories: For External Equipment

Digimatic mini processor DP-1VA

By connecting this printer to the Surftest SJ-310's digimatic

output, you can print calculation results, perform a variety

of statistical analyses, draw a histogram or D chart, and also

perform complicated operations for X-R control charts.

Calculation results input unit INPUT TOOL

This unit allows you to load Surftest SJ-310 calculation

results (SPC output) into commercial spreadsheet software

on a PC via a USB connector. You can essentially use a one-

touch operation to enter the calculation results (values) into

the cells in the spreadsheet software.

No.264-505A

USB Input Tool Direct

USB-ITN-D

No.06AFM380D

SJ-310

DP-1VA Connecting cable

1m: No.936937

2m: No.965014

USB keyboard signal conversion type*

IT-012U

No.264-016-10

* Requires the optional Surftest SJ-310

connection cable.

1m: No.936937

2m: No.965014

Footswitch

A footswitch is used to trigger measurement. This tool is

very useful in cases where you need to measure the same

workpiece multiple times using jigs and other fixtures.

Measurement Data Wireless Communication System U-WAVE

This unit allows you to remotely load Surftest SJ-310

calculation results (SPC output) into commercial spreadsheet

software on a PC.

You can essentially use a one-touch operation to enter the

calculation results (values) into the cells in the spreadsheet

software.

No.12AAJ088

U-WAVE-R

(Connects to the PC)

U-WAVE-T

*

(Connects to the SJ-310)

No.02AZD810DNo.02AZD880G

* Requires the optional Surftest SJ-310

connection cable.

No.02AZD790D

Optional accessories and consumables for SJ-310

• Printer paper (5 rolls)

• Durable printer paper (5 rolls)

• Touch-screen protector sheet (10 sheets)

• Memory card (2GB) *

• Connecting cable (for RS-232C)

No.270732

No.12AAA876

No.12AAN040

No.12AAL069

No.12AAA882

* micro SD card (with a conversion adapter to SD card)

11

Coordinate Measuring MachinesVision Measuring SystemsForm MeasurementOptical Measuring

Whatever your challenges are,

Mitutoyo supports you from start to finish.

Mitutoyo is not only a manufacturer of top-quality

measuring products but one that also offers qualified

support for the lifetime of the equipment, backed by

comprehensive services that ensure your staff can make

the very best use of the investment.

Sensor Systems

Test Equipment

and Seismometers

Digital Scale and DRO Systems

Small Tool Instruments

and Data Management

Apart from the basics of calibration and repair, Mitutoyo

offers product and metrology training, as well as IT

support for the sophisticated software used in modern

measuring technology. We can also design, build, test

and deliver measuring solutions and even, if deemed

cost-effective, take your critical measurement challenges

in-house on a sub-contract basis.

Find additional product literature

and our product catalog

Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance

data contained in this printed matter as well as other technical data are to be regarded as approximate average values. We

therefore reserve the right to make changes to the corresponding designs. The stated standards, similar technical regulations,

descriptions and illustrations of the products were valid at the time of printing. In addition, the latest applicable version of our

General Trading Conditions will apply. Only quotations submitted by ourselves may be regarded as definitive. Specifications

are subject to change without notice.

Mitutoyo products are subject to US Export Administration Regulations (EAR). Re-export or relocation of our products may

require prior approval by an appropriate governing authority.

Trademarks and Registrations

Designations used by companies to distinguish their products are often claimed as trademarks. In all instances where Mitutoyo

America Corporation is aware of a claim, the product names appear in initial capital or all capital letters. The appropriate

companies should be contacted for more complete trademark and registration information.

Mitutoyo America Corporation

One Number to Serve You Better

1-888-MITUTOYO (1-888-648-8869)

M

Solution Centers:

Aurora, Illinois (Headquarters)

Boston, Massachusetts

Charlotte, North Carolina

Cincinnati, Ohio

Detroit, Michigan

Los Angeles, California

Birmingham, Alabama

Seattle, Washington

Houston, Texas

2.5M 0214-02 WEB ONLY PDF Rev May 2018

3

©

2

0

1

8

M

i

t

u

t

o

y

o

A

m

e

r

i

c

a

C

o

r

p

o

r

a

t

i

o

n

2024年9月3日发(作者:薛夏青)

SURFTEST SJ-310 SERIES

PORTABLE SURFACE ROUGHNESS TESTER

F

O

R

M

M

E

A

S

U

R

E

M

E

N

T

Bulletin No. 2141(2)

The Surftest SJ-310 is a compact, portable, easy-to-use surface

roughness measurement instrument equipped with extensive

measurement and analysis features.

Easy to use

Large color graphic LCD

The color touch-screen provides excellent

readability and an intuitive display that is easy

to negotiate. The LCD also includes a backlight

for improved visibility in dark environments.

The integrated printer allows you to print

measurement results on the spot.

Enhanced power for making measurements on site

Despite its reduced charging time — approximately 1/4 that required for conventional

models, the Surftest SJ-310 is capable of making approximately 2.5 times the number

of measurements when fully charged. The detector supports a variety of measurement

orientations and can make measurements up against a wall surface or while facing upward.

When combined with optional accessories such as a height gauge adapter, the detector can

make measurements in various orientations and settings.

Highly functional

Internal memory

Up to 10 measurement conditions and one measured

profile can be stored in the internal memory.

Optional memory card

The optional memory card can be used as an

extended memory to store large quantities of

measured profiles and conditions and adds the

convenience of automatically saving data from

the 10 most recent measurements (Trace 10).

Password protection

Access to each feature can be password-protected,

which prevents unintended operations and allows

protection of your settings.

Multilingual support

The display interface supports 16 languages, which

can be freely switched.

Stylus alarm

(patent pending in Japan, U.S.A., EU)

An alarm warns you when the cumulative

measurement distance exceeds a preset limit.

Extensive analysis and display features

Complies with many industry standards

The Surftest SJ-310 complies with the following

standards: JIS (JIS-B0601-2001, JIS-B0601-1994, JIS

B0601-1982), VDA, ISO-1997, and ANSI.

Displays assessed profiles and graphical data

In addition to calculation results, the Surftest SJ-310

can display sectional calculation results and assessed

profiles, load curves, and amplitude distribution curves.

2

User friendly, high-functionality display unit with integrated high-speed printer

The large 5.7-inch color graphic touch-screen LCD provides excellent readability. Furthermore, selecting icons from the touch panel display*

1

provides intuitive and easy operation. The integrated high-speed printer also allows the user to perform the entire process from making

measurements to printing the results with the push of a single button (START button).

*1 Text display can also be selected.

Printer5.7-inch color graphic LCD

with touch screen

BAC and ADC curves can be printed in addition

to calculation results (including pass/fail results)

and assessed profiles. The printer offers an

easy-to-understand layout and can also print

horizontally to match the content displayed on the

LCD. Furthermore, printing speed is approximately

50% faster than conventional models.

Built-in battery

With drastically enhanced power compared

to conventional models, the Surftest SJ-310

can make 1,500 continuous measurements

on a full charge achieved in 4 hours.

Key-sheet buttons

Measurement Result

Measured profile

One-touch

switching

←→

BAC curve

ADC curve

Frequently used functions, such as the measurement start button,

are provided as rugged sheet buttons with excellent durability.

Highly functional detectors and drive units

Detector supplied

as standard

A wide range of optional detectors

is available, including detectors for

small holes, extra small holes, gear

tooth surfaces, and deep grooves.

Drive units

Standard drive unit

• Popular standard drive unit

Transverse tracing drive unit

Retractable drive unit

• Best suited for measurement

of narrow, shrouded workpiece

features such as crankshaft

bearings, EDM parts, etc.

(Patent Registered in Japan)

One of two types may be selected:

• The detector is in the retracted

position at rest so it is immune

from damage when inserted into

a feature whose shape cannot be

easily seen, such as a blind hole, etc.

Measuring force: 0.75mN

Stylus form: Tip radius 2µm

Tip angle 60°

Measuring force: 4mN

Stylus form: Tip radius 5µm

Tip angle 90°

Links to a wide variety of external instruments

You can save parameter recalculations and measurement results in text format on a memory card and import into commercial spreadsheet software

on a PC. You can also connect to a PC using the USB connector and use a dedicated software application to

perform everything from measurement control and condition modification to issuing inspection result reports.

PC

Memory card

(Option)

Side of display unit

U-WAVE-T *

2

USB I/F

RS-232C I/F

SPC I/F

USB Input Tool

Direct *

2

Input Tool

for USB *

2

U-WAVE-R *

2

Rear of display unit

DP-1VR *

2

*2: Refer to P11 for more details

3

Measurement assistance and analysis features

offering the ultimate in ease of use

Switches between icon and text display

The display can be switched between icon and text, providing easy, user-friendly operation.

Additionally, the guidance feature provides detailed explanations of touch-screen buttons.

IconText

Easy specification of assessment conditions from a list

Setting assessment conditions is simple because you can select the desired condition from a displayed list (e.g., standard, parameter).

Zooming waveforms and analyzing coordinate differences

You can not only

magnify or shrink

waveforms, but also

calculate the coordinate

difference between

two points using a ruler

operation.

You can quickly check

the irregularity status

without waiting for a

printout.

Deleting unnecessary data

With the Surftest

SJ-310, you can

delete portions of

measurement data.

This feature allows

you to make new

calculations by deleting

data that should not be

included in parameter

calculation, such as

data on a scratch.

Displaying pass/fail results

By specifying a tolerance in advance, you can display pass/fail results in color.

Surface texture symbol entry

You can enter assessment conditions using

ISO/JIS surface texture symbols.

(Patent registered in Japan, U.S.A., Germany, UK, France)

(Patent pending in China)

OK+NG-NG

4

Measurement results can be displayed in several ways

Measurement results can be presented in the form of a 1-parameter, profile, 4-parameter or trace display.

1-parameter display: one parameter

measurement result

Profile display: one parameter measurement

result and the measured profile

4-parameter display: four parameter

measurement results

Trace display: the ten latest measurement

results using the same parameter

Recalculation function

After completing measurement, you can modify the assessment conditions (standard, profile, and parameter) and easily recalculate the results using

the new condition.* *

Not possible with all measurement conditions.

Dual assessment of a single measurement

Using the result of a single measurement, you can make calculations or

analyze assessment profiles under two different assessment conditions

(standard, profile, filter, etc.) without using the recalculation feature.

Stylus alarm function

Displayed settings can be easily changed by pressing the left and right

arrow keys under the sliding cover. For example, these keys can be used

to switch the cut-off value(λc) and the number of sampling lengths (N)

on the measurement screen. (Patent pending in Japan.)

Positive stylus contact indication

Stylus contact with the workpiece is indicated by color coding

in the display. This is helpful when visibility of the surface to be

measured is restricted (e.g. when measuring within a shrouded

feature or groove).

Extensive statistical processing features

You can make a maximum of 300 statistical measurements using up to three

parameters to obtain averages, standard deviations, maximums, minimums,

passing rates, and histograms (upper and lower limits can be displayed).

This feature is ideal for day-to-day data management.

No contact Contact

5

Specifications

Specifications

Type of detector

Model No.

Order No.

X axis

inch/mm

Range

Range/

resolution

Standard drive unit typeRetractable drive unit typeTransverse tracing drive unit

SJ-310SJ-310SJ-310SJ-310SJ-310SJ-310

(0.75mN type)(4mN type)(0.75mN type)(4mN type)(0.75mN type)(4mN type)

178-571-01A178-571-02A178-573-01A178-573-02A178-575-01A178-575-02A

.7"(17.5 mm) .22"(5.6 mm)

14400 µinch (-7900 µinch to +6300 µinch) [360 µm (-200 µm ~ +160 µm)]

14400 µinch / .8 µinch (360 µm / 0.02 µm)

4000 µinch / .2 µinch (100 µm / 0.006 µm)

1000 µinch / .08 µinch (25 µm / 0.002 µm)

In the measurement: .01inch/s (0.25mm/s), .02inch/s (0.5mm/s), .03inch/s (0.75mm/s), In the return: .04inch/s (1mm/s)

0.75mN type: 0.75mN / 2µmR 60°, 4mN type: 4mN / 5µmR 90°

400mN or less

JIS’82 / JIS’94 / JIS’01 / ISO’97 / ANSI / VDA / FREE

Primary(P), Roughness(R), DF, R-Motif, W-Motif

Ra, Rc, Ry, Rz, Rq, Rt, Rmax*

1

, Rp, Rv, R3z, Rsk, Rku, Rc, RPc, Rsm, Rz1max*

2

, S, HSC, RzJIS*

3

, Rppi, R

a, R

q, Rlr, Rmr,

Rmr

(

c

)

, Rδc, Rk, Rpk, Rvk, Mr1, Mr2, A1, A2, Vo, λa, λq, L

0

, Rpm, tp*

4

, Htp*

4

, R, Rx, AR, W, AW, Wx, Wte, Possible Customize

BAC and ADC curves

Gaussian, 2CR75, PC75

.003, .01, .03, .1, .3" (0.08, 0.25, 0.8, 2.5, 8 mm)

100, 320 µinch (2.5, 8 µm)

.003, .01, .03, .1, .3" (0.08, 0.25, 0.8, 2.5, 8 mm)

×1, ×2, ×3, ×4, ×5, ×6, ×7, ×8, ×9, ×10,

×1, ×2, ×3, ×4, ×5, ×6, ×7, ×8, ×9, ×10, Arbitrary

Arbitrary .0118 ~ .22"(.0001" Interval)

.0118 ~ .6299"(.0001" Interval) [(0.3 ~ 16.0mm: 0.01mm Interval)]

[(0.3 ~ 5.6mm: 0.01mm Interval)]

4.64" x 3.47" (117.8 × 88.2 mm)

Japanese, English, German, French, Italian, Spanish, Portuguese, Korean,

Traditional Chinese, Simplified Chinese, Czech, Polish, Hungarian Turkish, Swedish, Dutch

1-parameter display: one parameter measurement result

4-parameter display: four parameter measurement results

Profile display: one parameter measurement result and the measured profile

Trace display: The ten latest measurement results using the same parameter

Measurement conditions / Calculation results / GO / NG judgement result / Calculation results for each sampling length /

Measurement curve / BAC / ADC / Environmental setting information

USB I/F, Digimatic output, RS-232C I/F, External SW I/F

Desired parameters can be selected for calculation and display

Max rule / 16% rule / Average rule / Standard deviation (1

σ

, 2

σ

, 3

σ

)

Save the condition at power OFF

Internal memory: Measurement condition (10 sets)

Memory card (option): 500 measurement conditions, 1000 measuring data, 10000 text data, 500 statistic data,

500 image data, 1 backup of machine setting, the last ten traces (Trace 10)

Saves last inputted nominal value of specimen / Average calibration with multiple measurement (MAX.12 times) is available

Auto-sleep function (30-600sec) *

7

Two-way power supply: battery (rechargeable Ni-MH battery) and AC adapter

*Charging time: about 4 hours (may vary due to ambient temperature)

*Endurance: about 1500 measurements (differs slightly due to use conditions / environment)

10.8"x 4.3" x 7.8"(275 × 109 × 198 mm)

4.5"x 0.9" x 8.9"(115 × 23 × 26.7 mm)

About 1.8kg (Display unit + Drive unit + Standard detector)

12AAM475

12AAA217

12AAA218

12AAA216

12BAK700

12BAG834

12BAL402

270732

12BAL400

178-602

357651

02ZAA010

Connecting cable *

8

Nosepiece for plane surface

Nosepiece for cylinder

Supporting leg

Calibration stage

Stylus pen

Protection sheet

Printer paper (5 pieces)

Carrying case

Roughness reference specimen (Ra 119µin/3µm)

AC Adapter

Power Cord set (UL/CSA)

12AAM475

12AAE643

12AAE644

12BAK700

12BAG834

12BAL402

270732

12BAL400

178-606

357651

02ZAA010

Connecting cable *

8

Point-contact adapter

V-type adapter

Calibration stage

Stylus pen

Protection sheet

Printer paper (5 pieces)

Carrying case

Roughness Reference Specimen

(Ra 0.039µin/1.0µm)

AC Adapter

Power Cord set (UL/CSA)

Measuring

range

Detector

Measuring speed

Measuring force / Stylus tip

Skid force

Standard

Measured profiles

Parameters

Graph analysis

Filter

Cut-off length

Sampling length

λ

c

λ

s *

5

Number of sampling lengths

LCD dimensions

Display languages

Measurement result display

Printing function

External I/O

Customization

GO/ NG judgement *

6

Storage of measurement

condition

Storage

Calibration

Power-saving

Power supply

Size (W×D×H)

Mass

Display unit

Drive unit

Functions

Standard accessories

Philips screwdriver, Strap for stylus pen, Operation manual, Quick reference manual, Warranty

*1: Only for VDA/ANSI/JIS’82 standards.

*2: Only for JIS’97 standard.

*3: Only for JIS’01 standard.

*4: Only for ANSI standard.

*5:

λ

s may not be switchable depending on a standard selected.

*6: Standard deviation only can be selected in ANSI.16% rule cannot be selected in VDA.

*7: Auto-sleep function is invalid when AC adapter is used.

*8: For connecting the calculation display unit and drive unit.

6

Dimensions: Display Unit and Drive Unit

Drive unit, Display unit

Drive unit type

0

.

9

1

(

2

3

.

0

)

Unit: inch(mm)

Drive unit external view

Standard drive unit

1

.

0

2

(

2

6

.

0

)

0.99”(25.2)

1.05”(26.7)4.53”(115.0)

0.08”(2.0)

0.91”(23.2)

1.05”(26.7)

4.53”(115.0)

Transverse tracing drive unit

0.118”(3.0)

0.26”(6.6)

1

.

0

2

(

2

6

.

0

)

0

.

9

1

(

2

3

.

0

)

.

0

3

9

(

1

)

1.8”(45.5)

1.85”(47)4.53”(115.0)

Retractable drive unit

Display unit external view

Cable length: 1m

1

.

0

2

(

2

6

.

0

)

0

.

9

1

(

2

3

.

0

)

10.83”(275)

4.29”(109)

7

.

8

(

1

9

8

)

1

5

°

7

Dimensions: Detectors

Detectors

Standard detectors

16.4

6

3.5

61

Stylus

ф

9

ф

2

Unit: mm

Gear-tooth surface detectors

R

4

0

0

.

9

12.6

6

0

°

0

.

4

1

.

8

60.1

Stylus

2

.

4

4.8

1.5

59.5

0.6

1.4

Stylus

Order No.

Measuring

force form*

178-2960.75mN 2 µmR/60˚

178-3904 mN 5 µmR/90˚

178-3870.75mN 2 µmR/60˚

178-3864 mN 5 µmR/90˚

178-3950.75mN 2 µmR/90˚

178-3914 mN10 µmR/90˚

*Tip radius / Tip angle

Remarks

Dedicated to the

standard/retractable

drive unit

Dedicated to the

transverse tracing

drive unit

Dedicated to the

standard/retractable

drive unit

Order No.

178-388

178-398

Measuring

force

0.75mN

4 mN

Stylus form*

2 µmR/60˚

5 µmR/60˚

*Tip radius / Tip angle

Small hole detectors

ф

Deep groove detectors

3

.

8

16.2

60.7

Stylus

3.5

9

1

3

.

6

16.4

61

Stylus

ф

9

ф

9

1.5

2

1.5

4.8

Stylus

Order No.

Measuring

Remarks

force form*

178-3830.75mN2 µmR/60˚

Minimum

measurable hole

178-3924 mN5 µmR/90˚

diameter:

ø

4.5mm

*Tip radius / Tip angle

Stylus

Order No.

Measuring

Remarks

force form*

178-3850.75mN2 µmR/60˚

Not available for the

transverse tracing

178-3944 mN5 µmR/90˚

drive unit

*Tip radius / Tip angle

Extra small hole detectors

ф

2

.

4

12.8

60.3

Stylus

ф

9

0

.

4

0.8

*Tip radius / Tip angle

Stylus

Order No.

Measuring

Remarks

force form*

178-3840.75mN2 µmR/60˚

Minimum

measurable hole

178-3934 mN5 µmR/90˚

diameter: ø2.8mm

8

1

.

8

1.6

1

0

3.5

4.8

ф

9

.

4

Dimensions: Display Unit and Drive Unit

Drive unit, Display unit

Nosepiece for flat surfaces

No.12AAA217

• SJ-310/310R standard accessories

• Not available for the transverse

tracing drive unit.

Nosepiece for flat surface

No.12AAA217

Nosepiece for cylindrical surfaces

No.12AAA218

• SJ-310/310R standard accessories

• Not available for the transverse

tracing drive unit.

• ø30mm or smaller workpiece.

Nosepiece for

cylindrical surface

No.12AAA218

V-type adapter

No.12AAE644

• SJ-310S standard accessories

• Dedicated to the transverse tracing

drive unit.

7.7mm

7

2

m

m

Point-contact adapter

No.12AAE643

• SJ-310S standard accessories

• Dedicated to the transverse

tracing drive unit.

Extension rod (50 mm)

No.12AAA210

• Not available for the transverse

tracing drive unit.

Extension rod 50 mm

No.12AAA210

Extension cable (1 m)

No.12BAA303

• For connecting calculation display unit and drive unit.

Support feet set

No.12AAA216

• SJ-310 standard

accessory

• Not attachable to

the detector side

of the transverse

tracing drive unit.

Support feet set

No.12AAA216

Vertical positioning adapter

No.12AAA219

• Not available for the

transverse tracing drive unit

Detector side

Vertical positioning

adapter

No.12AAA219

Magnetic stand adapter

No.12AAA221(ø8mm)

No.12AAA220(ø9.5mm)

Magnetic stand

adapter

Height gage adapter

No.12AAA222(9x9mm)

No.12AAA233(1/4inx1/2in)

Height gage adapter

Setting attachments

(Note: Not available for the transverse tracing drive unit)

Enhances measurement efficiency by facilitating the measurement setup of multiple workpieces of the same type and of the hard-to-access

sections of a workpiece.

V-type for measuring axially

No.178-033

The V-width is adjustable

to the cylindrical workpiece

diameter, facilitating axial

measurement of a wide

range workpiece sizes.

• Adjustable range:

ø 5 ~ 150 mm

Slider type

No.178-034

This attachment is ideal for measuring

a flat area of a workpiece that has

an indentation or step that makes it

difficult to attach the drive unit. You

can further improve the ease of use

by using this attachment with the

magnetic installation base (option:

No. 12AAA910).

Inside diameter type

No.178-035

Greatly facilitates measurement

of internal wall surfaces of, for

example, a cylinder block.

• Applicable diameter:

ø 75 ~ ø 95 mm

• Accessible depth:

30 ~ 135 mm

9

Optional Accessories: For External Output

Simplified communication program for SURFTEST SJ series

The Surftest SJ-310 series has a USB interface, enabling data to be transferred to a spreadsheet or other software.

We also provide a program that lets you create inspection record tables using a Microsoft Excel* macro.

Required environment*:

• OS:

• Spreadsheet software:

Windows XP-SP3

Microsoft Excel 2000/2002/

Windows Vista

2003/2007/2010/2013/2016

Windows 7/8/10

*Windows OS and Microsoft Excel are products of

Microsoft Corporation.

Required environment*:

• USB cable for SJ-310 series

No. 12AAD510

This program can be downloaded free of charge from

the Mitutoyo website.

Contour / Roughness analysis software FORMTRACEPAK

More advanced analysis can be performed by loading SJ-310 series measurement data to software program FORMTRACEPAK

via a memory card (option) for processing back at base.

10

Optional Accessories: For External Equipment

Digimatic mini processor DP-1VA

By connecting this printer to the Surftest SJ-310's digimatic

output, you can print calculation results, perform a variety

of statistical analyses, draw a histogram or D chart, and also

perform complicated operations for X-R control charts.

Calculation results input unit INPUT TOOL

This unit allows you to load Surftest SJ-310 calculation

results (SPC output) into commercial spreadsheet software

on a PC via a USB connector. You can essentially use a one-

touch operation to enter the calculation results (values) into

the cells in the spreadsheet software.

No.264-505A

USB Input Tool Direct

USB-ITN-D

No.06AFM380D

SJ-310

DP-1VA Connecting cable

1m: No.936937

2m: No.965014

USB keyboard signal conversion type*

IT-012U

No.264-016-10

* Requires the optional Surftest SJ-310

connection cable.

1m: No.936937

2m: No.965014

Footswitch

A footswitch is used to trigger measurement. This tool is

very useful in cases where you need to measure the same

workpiece multiple times using jigs and other fixtures.

Measurement Data Wireless Communication System U-WAVE

This unit allows you to remotely load Surftest SJ-310

calculation results (SPC output) into commercial spreadsheet

software on a PC.

You can essentially use a one-touch operation to enter the

calculation results (values) into the cells in the spreadsheet

software.

No.12AAJ088

U-WAVE-R

(Connects to the PC)

U-WAVE-T

*

(Connects to the SJ-310)

No.02AZD810DNo.02AZD880G

* Requires the optional Surftest SJ-310

connection cable.

No.02AZD790D

Optional accessories and consumables for SJ-310

• Printer paper (5 rolls)

• Durable printer paper (5 rolls)

• Touch-screen protector sheet (10 sheets)

• Memory card (2GB) *

• Connecting cable (for RS-232C)

No.270732

No.12AAA876

No.12AAN040

No.12AAL069

No.12AAA882

* micro SD card (with a conversion adapter to SD card)

11

Coordinate Measuring MachinesVision Measuring SystemsForm MeasurementOptical Measuring

Whatever your challenges are,

Mitutoyo supports you from start to finish.

Mitutoyo is not only a manufacturer of top-quality

measuring products but one that also offers qualified

support for the lifetime of the equipment, backed by

comprehensive services that ensure your staff can make

the very best use of the investment.

Sensor Systems

Test Equipment

and Seismometers

Digital Scale and DRO Systems

Small Tool Instruments

and Data Management

Apart from the basics of calibration and repair, Mitutoyo

offers product and metrology training, as well as IT

support for the sophisticated software used in modern

measuring technology. We can also design, build, test

and deliver measuring solutions and even, if deemed

cost-effective, take your critical measurement challenges

in-house on a sub-contract basis.

Find additional product literature

and our product catalog

Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance

data contained in this printed matter as well as other technical data are to be regarded as approximate average values. We

therefore reserve the right to make changes to the corresponding designs. The stated standards, similar technical regulations,

descriptions and illustrations of the products were valid at the time of printing. In addition, the latest applicable version of our

General Trading Conditions will apply. Only quotations submitted by ourselves may be regarded as definitive. Specifications

are subject to change without notice.

Mitutoyo products are subject to US Export Administration Regulations (EAR). Re-export or relocation of our products may

require prior approval by an appropriate governing authority.

Trademarks and Registrations

Designations used by companies to distinguish their products are often claimed as trademarks. In all instances where Mitutoyo

America Corporation is aware of a claim, the product names appear in initial capital or all capital letters. The appropriate

companies should be contacted for more complete trademark and registration information.

Mitutoyo America Corporation

One Number to Serve You Better

1-888-MITUTOYO (1-888-648-8869)

M

Solution Centers:

Aurora, Illinois (Headquarters)

Boston, Massachusetts

Charlotte, North Carolina

Cincinnati, Ohio

Detroit, Michigan

Los Angeles, California

Birmingham, Alabama

Seattle, Washington

Houston, Texas

2.5M 0214-02 WEB ONLY PDF Rev May 2018

3

©

2

0

1

8

M

i

t

u

t

o

y

o

A

m

e

r

i

c

a

C

o

r

p

o

r

a

t

i

o

n

发布评论

评论列表 (0)

  1. 暂无评论