2024年9月11日发(作者:羊舌宵月)
NPort6400/6600Series
4/8/16/32-portRS-232/422/485secureterminalservers
FeaturesandBenefits
•
LCDpanelforeasyIPaddressconfiguration()
•
SecureoperationmodesforRealCOM,TCPServer,TCPClient,Pair
Connection,Terminal,andReverseTerminal
•
Nonstandardbaudratessupportedwithhighprecision
•
PortbuffersforstoringserialdatawhentheEthernetisoffline
•
SupportsIPv6
•
Ethernetredundancy(STP/RSTP/TurboRing)withnetworkmodule
•
GenericserialcommandssupportedinCommand-by-Commandmode
•
SecurityfeaturesbasedonIEC62443
Certifications
Introduction
TheNPort®6000isaterminalserverthatuse32serialdevices
ofanytypecanbeconnectedtotheNPort®6000,ernetportcanbeconfiguredforanormalorsecureTCP/IP
rt®6000securedeviceserversaretherightchoiceforapplicationsthatuselargenumbersofserialdevicespackedintoa
tybreachesareintolerableandtheNPort®6000SeriesensuresdatatransmissionintegritywithsupportforDES,3DES,and
devicesofanytypecanbeconnectedtotheNPort®6000,andeachserialportontheNPort®6000canbe
configuredindependentlyforRS-232,RS-422,orRS-485transmission.
NoDataLossIfEthernetConnectionFails
TheNPort®6000isareliabledeviceserverthatprovidesuserswithsecureserial-to-Ethernetdatatransmissionandacustomer-orientedhardware
thernetconnectionfails,theNPort®eEthernetconnectionis
re-established,theNPort®6000willanincreasetheportbuffer
sizebyinstallinganSDcard.
LCDPanelMakesConfigurationEasy
TheNPort®el
displaystheservername,serialnumber,andIPaddress,andanyof
thedeviceserver’sconfigurationparameters,suchasIPaddress,
netmask,andgatewayaddress,canbeupdatedeasilyandquickly.
Note:TheLCDpanelisonlyavailablewithstandard-temperature
models.
AdjustableResistorValuesforRS-485Communication
TheNPort®6600providesadjustabletermination,pullhigh,andpull
critical
environments,terminationresistorsmaybeneededtopreventthe
reflectionofserialsignals,andthepullhighandpulllowresistorsmay
nosetofresistorvaluesworksforeveryenvironment,theNPort®
6600allowsmanualadjustmentoftheresistorvaluesforeachserial
portusingbuilt-inDIPswitches.
1
Specifications
Memory
SDSlotUpto32GB(SD2.0compatible)
Input/OutputInterface
AlarmContactChannelsResistiveload:1A@24VDC
EthernetInterface
10/100BaseT(X)Ports(RJ45connector)1
AutoMDI/MDI-Xconnection
1.5kV(built-in)
NMSeriesexpansionmodulesforoptionalextensionofRJ45andfiberEthernetports
800
TypicalDistance
Typical(nm)
WavelengthTXRange(nm)
RXRange(nm)
TXRange(dBm)
RXRange(dBm)
OpticalPower
LinkBudget(dB)
DispersionPenalty
(dB)
4km
1300
1260to1360
1100to1600
-10to-20
-3to-32
12
3
5km40km
1310
1280to1340
1100to1600
0to-5
-3to-34
29
1
MagneticIsolationProtection
CompatibleModules
OpticalFiber
Note:Whenconnectingasingle-modefibertransceiver,werecommendusingan
attenuatortopreventdamagecausedbyexcessiveopticalpower.
Note:Computethe“typicaldistance”ofaspecificfibertransceiverasfollows:Link
budget(dB)>dispersionpenalty(dB)+totallinkloss(dB).
EthernetSoftwareFeatures
ConfigurationOptionsWebConsole(HTTP/HTTPS),WindowsUtility,DeviceSearchUtility(DSU),MCCTool,
SerialConsole,Telnet/SSHConsole
ARP,BOOTP,DHCPClient,DNS,HTTP,ICMP,IPv4/IPv6,PPPOE,SMTP,SNMPv1/v2c/
v3,SNTP,TCP/IP,Telnet,UDP
Windows95/98/ME/NT/2000,WindowsXP/2003/Vista/2008/7/8/8.1/10(x86/x64),
Windows2008R2/2012/2012R2/2016/2019(x64),WindowsEmbeddedCE5.0/6.0,
WindowsXPEmbedded
Kernelversions:2.4.x,2.6.x,3.x,4.x,and5.x
SCOUNIX,SCOOpenServer,UnixWare7,QNX4.25,QNX6.x,Solaris10,FreeBSD,AIX
5.x,HP-UX11i,MacOSX,macOS10.12,macOS10.13,macOS10.14,macOS10.15
ter
MIB-II
SNTPClient
Management
WindowsRealCOMDrivers
LinuxRealTTYDrivers
FixedTTYDrivers
AndroidAPI
MIB
TimeManagement
2
UnicastRouting
Authentication
RIPV1/V2,StaticRoute
LocalAccountAccessibility,RADIUS,TACACS+
SerialInterface
ConnectorNPort6600Models:8-pinRJ45
NPort6450Models:DB9male
NPort6450Models:4
NPort6600-8Models:8
NPort6600-16Models:16
NPort6600-32Models:32
NPort6610Models:RS-232
NPort6450/6650Models:RS-232/422/485
ReverseSSH,SecurePairConnection,SecureRealCOM,SecureTCPClient,Secure
TCPServer,SSH
Disabled,EthernetModem,PairConnection,PPP,Printer,RealCOM,ReverseTelnet,
RFC2217,TCPClient,TCPServer,Terminal,UDP
50bpsto921.6kbps(supportsnon-standardbaudrates)
NPort6600Models:RS-232(TxD,RxD,GND),8-pinRJ45(19200,n,8,1)
5,6,7,8
1,1.5,2
None,Even,Odd,Space,Mark
RTS/CTS,DTR/DSR,XON/XOFF
NPort6450/6650Models:1kilo-ohm,150kilo-ohms
NPort6450/6650Models:supportADDC®(automaticdatadirectioncontrol)
NPort6450/6650Models:120ohms
s
SerialStandards
SecureOperationModes
StandardOperationModes
Baudrate
ConsolePort
DataBits
StopBits
Parity
FlowControl
PullHigh/LowResistorforRS-485
RS-485DataDirectionControl
TerminatorforRS-485
SerialSignals
RS-232
RS-422
RS-485-4w
RS-485-2w
TxD,RxD,RTS,CTS,DTR,DSR,DCD,GND
Tx+,Tx-,Rx+,Rx-,GND
Tx+,Tx-,Rx+,Rx-,GND
Data+,Data-,GND
PowerParameters
InputCurrentNPort6450Models:730mA@12VDC
NPort6600Models:
DCModels:293mA@48VDC,200mA@88VDC
ACModels:140mA@100VAC(8ports),192mA@100VAC(16ports),285mA@100
VAC(32ports)
InputVoltageNPort6450Models:12to48VDC
NPort6600Models:
ACModels:100to240VAC
DC-48VModels:±48VDC(20to72VDC,-20to-72VDC)
DC-HVModels:110VDC(88to300VDC)
3
Reliability
AutomaticRebootTrigger
AlertTools
Built-inWDT
Built-inbuzzerandRTC(real-timeclock)
PhysicalCharacteristics
Housing
Dimensions(withears)
Metal
NPort6450Models:181x103x35mm(7.13x4.06x1.38in)
NPort6600Models:480x195x44mm(18.9x7.68x1.73in)
NPort6450Models:158x103x35mm(6.22x4.06x1.38in)
NPort6600Models:440x195x44mm(17.32x7.68x1.73in)
NPort6450Models:1,020g(2.25lb)
NPort6600-8Models:3,460g(7.63lb)
NPort6600-16Models:3,580g(7.89lb)
NPort6600-32Models:3,600g(7.94lb)
LCDpaneldisplay(non-Tmodelsonly)
Pushbuttonsforconfiguration(non-Tmodelsonly)
NPort6450Models:Desktop,DIN-railmounting,Wallmounting
NPort6600Models:Rackmounting(withoptionalkit)
Dimensions(withoutears)
Weight
InteractiveInterface
Installation
EnvironmentalLimits
OperatingTemperatureStandardModels:0to55°C(32to131°F)
-HVModels:-40to85°C(-40to185°F)
Allother-TModels:-40to75°C(-40to167°F)
StandardModels:-40to75°C(-40to167°F)
-HVModels:-40to85°C(-40to185°F)
Allother-TModels:-40to75°C(-40to167°F)
5to95%(non-condensing)
StorageTemperature(packageincluded)
AmbientRelativeHumidity
StandardsandCertifications
EMC
EMI
EMS
EN55032/24
CISPR32,FCCPart15BClassA
NPort6450Models:
IEC61000-4-2ESD:Contact:4kV;Air:8kV
IEC61000-4-3RS:80MHzto1GHz:3V/m
IEC61000-4-4EFT:Power:1kV;Signal:0.5kV
IEC61000-4-5Surge:Power:1kV
IEC61000-4-6CS:150kHzto80MHz:3V/m;Signal:3V/m
IEC61000-4-8PFMF
IEC61000-4-11
NPort6600Models(except-48V/-HVmodels):
IEC61000-4-2ESD:Contact:4kV;Air:8kV
IEC61000-4-3RS:80MHzto1GHz:3V/m
IEC61000-4-4EFT:Power1kV;Signal0.5kV
IEC61000-4-5Surge:Power:2kV
IEC61000-4-6CS:150kHzto80MHz:3V/m;Signal:3V/m
IEC61000-4-8PFMF
IEC61000-4-11
NPort6600-48VModels:
IEC61000-4-2ESD:Contact:4kV;Air:8kV
IEC61000-4-3RS:80MHzto1GHz:3V/m
IEC61000-4-4EFT:Power:1kV;Signal:0.5kV
IEC61000-4-5Surge:Power:1kV
IEC61000-4-6CS:150kHzto80MHz:3V/m;Signal:3V/m
IEC61000-4-8PFMF
NPort6650-HVModels:
IEC61000-4-2ESD:Contact:4kV;Air:8kV
4
IEC61000-4-3RS:80MHzto1GHz:3V/m
IEC61000-4-4EFT:Power:4kV;Signal:2kV
IEC61000-4-5Surge:Power:2kV
IEC61000-4-6CS:150kHzto80MHz:3V/m;Signal:3V/m
IEC61000-4-8PFMF
Safety
TrafficControl
Vibration
Freefall
UL60950-1
NEMATS2
IEC60068-2-6
IEC60068-2-34
Declaration
GreenProductRoHS,CRoHS,WEEE
MTBF
TimeNPort6450Models:850,905hrs
NPort6610-8Models:135,891hrs
NPort6610-16Models:102,373hrs
NPort6610-32Models:68,707hrs
NPort6650-8Models:636,600hrs
NPort6650-16Models:439,673hrs
NPort6650-32Models:310,078hrs
NPort6650-8-HV-T:501,171hrs
NPort6650-16-HV-T:380,006hrs
NPort6650-32-HV-T:290,914hrs
NPort6450Models:Telcordia(Bellcore)StandardTR/SR
NPort6600Models:Telcordia(Bellcore)Standard
Standards
Warranty
WarrantyPeriod
Details
5years
/warranty
PackageContents
Device
InstallationKit
Cable
PowerSupply
1xNPort6400/6600Seriesterminalserver
2xrack-mountingear(NPort6600models)
1xDB9maletoRJ458-pin(NPort6600models)
1xpowercable,suitableforyourregion(ACmodelsexcept-Tmodels)
1xpoweradapter,suitableforyourregion(NPort6450)
1xquickinstallationguide
1xwarrantycard
Documentation
5
Dimensions
NPort6450NPort6600
OrderingInformation
ModelName
NPort6450
NPort6450-T
NPort6610-8
NPort6610-8-48V
NPort6610-16
NPort6610-16-48V
NPort6610-32
NPort6610-32-48V
NPort6650-8
NPort6650-8-T
NPort6650-8-HV-T
alPorts
4
4
8
8
16
16
32
32
8
8
8
SerialStandards
RS-232/422/485
RS-232/422/485
RS-232
RS-232
RS-232
RS-232
RS-232
RS-232
RS-232/422/485
RS-232/422/485
RS-232/422/485
SerialInterface
DB9male
DB9male
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
OperatingTemp.
0to55°C
-40to75°C
0to55°C
0to55°C
0to55°C
0to55°C
0to55°C
0to55°C
0to55°C
-40to75°C
-40to85°C
InputVoltage
12to48VDC
12to48VDC
100-240VAC
48VDC;+20to+72
VDC,-20to-72VDC
100-240VAC
48VDC;+20to+72
VDC,-20to-72VDC
100-240VAC
48VDC;+20to+72
VDC,-20to-72VDC
100-240VAC
100-240VAC
110VDC;88to300
VDC
48VDC;+20to+72
VDC,-20to-72VDC
100-240VAC
48VDC;+20to+72
VDC,-20to-72VDC
100-240VAC
110VDC;88to300
VDC
100-240VAC
NPort6650-8-48V
NPort6650-16
NPort6650-16-48V
NPort6650-16-T
NPort6650-16-HV-T
NPort6650-32
8
16
16
16
16
32
RS-232/422/485
RS-232/422/485
RS-232/422/485
RS-232/422/485
RS-232/422/485
RS-232/422/485
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
0to55°C
0to55°C
0to55°C
-40to75°C
-40to85°C
0to55°C
6
NPort6650-32-48V32RS-232/422/4858-pinRJ450to55°C
48VDC;+20to+72
VDC,-20to-72VDC
110VDC;88to300
VDC
NPort6650-32-HV-T32RS-232/422/4858-pinRJ45-40to85°C
Accessories(soldseparately)
Cables
CBL-RJ45F25-1508-pinRJ45toDB25femaleserialcable,1.5m
ApplicableModels:
NPort6650-8-48V
NPort6650-8-HV-T
NPort6650-32-48V
NPort6650-32-HV-T
NPort6650-16-HV-T
NPort6650-16-48V
CBL-RJ45F9-1508-pinRJ45toDB9femaleserialcable,1.5m
ApplicableModels:
NPort6650-16
NPort6650-8-48V
NPort6610-32-48V
NPort6650-16-48V
NPort6650-16-T
NPort6650-8
NPort6650-8-HV-T
NPort6610-16
NPort6650-32-HV-T
NPort6610-8
NPort6650-32-48V
NPort6650-16-HV-T
NPort6610-32
NPort6610-16-48V
NPort6610-8-48V
NPort6650-8-T
NPort6650-32
CBL-RJ45M25-1508-pinRJ45toDB25maleserialcable,1.5m
ApplicableModels:
NPort6650-8
NPort6650-8-HV-T
NPort6610-16
NPort6650-8-T
NPort6610-32-48V
NPort6650-16-T
NPort6650-8-48V
NPort6650-16-HV-T
NPort6650-16-48V
NPort6650-16
NPort6650-32-HV-T
NPort6650-32
NPort6610-8
NPort6610-8-48V
NPort6650-32-48V
NPort6610-16-48V
NPort6610-32
CBL-RJ45M9-1508-pinRJ45toDB9maleserialcable,1.5m
ApplicableModels:
NPort6610-32-48V
NPort6610-8-48V
NPort6650-32
NPort6650-8
NPort6650-32-HV-T
NPort6610-16
NPort6610-8
NPort6650-8-48V
7
NPort6650-16
NPort6650-16-HV-T
NPort6610-16-48V
NPort6610-32
NPort6650-32-48V
NPort6650-8-T
NPort6650-16-T
NPort6650-8-HV-T
NPort6650-16-48V
CBL-RJ45SF25-1508-pinRJ45toDB25femaleserialcablewithshielding,1.5m
ApplicableModels:
NPort6610-16
NPort6610-32-48V
NPort6610-32
NPort6650-32
NPort6650-32-48V
NPort6610-8
NPort6650-16-T
NPort6610-16-48V
NPort6650-32-HV-T
NPort6650-16
NPort6650-8
NPort6650-16-48V
NPort6650-16-HV-T
NPort6650-8-T
NPort6610-8-48V
NPort6650-8-48V
NPort6650-8-HV-T
CBL-RJ45SF9-1508-pinRJ45toDB9femaleserialcablewithshielding,1.5m
ApplicableModels:
NPort6610-32
NPort6650-8
NPort6650-32
NPort6650-8-HV-T
NPort6650-16-HV-T
NPort6610-8
NPort6650-16
NPort6610-16
NPort6650-16-48V
NPort6650-8-T
NPort6650-8-48V
NPort6650-32-48V
NPort6650-16-T
NPort6610-32-48V
NPort6610-8-48V
NPort6610-16-48V
NPort6650-32-HV-T
CBL-RJ45SM25-1508-pinRJ45toDB25maleserialcablewithshielding,1.5m
ApplicableModels:
NPort6650-8
NPort6650-8-48V
NPort6610-32-48V
NPort6650-8-T
NPort6650-32-HV-T
NPort6650-32
NPort6610-16
NPort6650-16
NPort6610-8-48V
NPort6650-16-T
NPort6610-8
NPort6610-16-48V
NPort6650-16-48V
NPort6610-32
NPort6650-8-HV-T
NPort6650-32-48V
NPort6650-16-HV-T
CBL-RJ45SM9-1508-pinRJ45toDB9maleserialcablewithshielding,1.5m
ApplicableModels:
NPort6610-16
8
NPort6650-32
NPort6650-8-T
NPort6610-32-48V
NPort6610-16-48V
NPort6650-16-48V
NPort6610-8
NPort6650-32-HV-T
NPort6610-8-48V
NPort6650-16-HV-T
NPort6650-32-48V
NPort6650-8-HV-T
NPort6650-16-T
NPort6610-32
NPort6650-8-48V
NPort6650-16
NPort6650-8
Connectors
MiniDB9F-to-TBDB9femaletoterminalblockconnector
ApplicableModels:
NPort6450
NPort6450-T
DIN-RailMountingKits
DK35ADIN-railmountingkit,35mm
ApplicableModels:
NPort6450
NPort6450-T
ExpansionModules
NM-TX01
NM-TX01-T
NM-TX02
NM-TX02-T
NM-FX01-M-SC
NM-FX01-M-SC-T
NM-FX01-S-SC
NM-FX01-S-SC-T
NM-FX02-M-SC
NM-FX02-M-SC-T
NM-FX02-S-SC
NM-FX02-S-SC-T
110/100BaseTXport
110/100BaseTXport,-40to75°Coperatingtemperature
210/100BaseTXports
210/100BaseTXports,-40to75°Coperatingtemperature
1100BaseFXport,multi-mode,SCconnector
1100BaseFXport,multi-mode,SCconnector,-40to75°Coperatingtemperature
1100BaseFXport,single-mode,SCconnector
1100BaseFXport,single-mode,SCconnector,-40to75°Coperatingtemperature
2100BaseFXports,multi-mode,SCconnector
2100BaseFXports,multi-mode,SCconnector,-40to75°Coperatingtemperature
2100BaseFXports,single-mode,SCconnector
2100BaseFXports,single-mode,SCconnector,-40to75°Coperatingtemperature
PowerAdapters
PWR-12125-DT-S2Desktoppowersupply(requirespowercord),12VDC,1.25A,100to240VAC,0to40°Coperating
temperature
ApplicableModels:
NPort6450
NPort6450-T
PWR-12150-AU-SA-TLockingbarrelplug,12VDC,1.5A,100to240VAC,Australia(AU)plug,-40to75°Coperating
temperature
ApplicableModels:
NPort6450-T
NPort6650-16-HV-T
NPort6650-16-T
NPort6650-32-HV-T
NPort6650-8-HV-T
NPort6650-8-T
9
PWR-12150-CN-SA-TLockingbarrelplug,12VDC,1.5A,100to240VAC,China(CN)plug,-40to75°Coperating
temperature
ApplicableModels:
NPort6450-T
NPort6650-16-HV-T
NPort6650-16-T
NPort6650-32-HV-T
NPort6650-8-HV-T
NPort6650-8-T
PWR-12150-EU-SA-TLockingbarrelplug,12VDC,1.5A,100to240VAC,ContinentalEurope(EU)plug,-40to75°C
operatingtemperature
ApplicableModels:
NPort6450-T
NPort6650-16-HV-T
NPort6650-16-T
NPort6650-32-HV-T
NPort6650-8-HV-T
NPort6650-8-T
PWR-12150-UK-SA-TLockingbarrelplug,12VDC,1.5A,100to240VAC,UnitedKingdom(UK)plug,-40to75°Coperating
temperature
ApplicableModels:
NPort6450-T
NPort6650-16-HV-T
NPort6650-16-T
NPort6650-32-HV-T
NPort6650-8-HV-T
NPort6650-8-T
PWR-12150-USJP-SA-TLockingbarrelplug,12VDC1.5A,100to240VAC,UnitedStates/Japan(US/JP)plug,-40to75°C
operatingtemperature
ApplicableModels:
NPort6450-T
NPort6650-16-HV-T
NPort6650-16-T
NPort6650-32-HV-T
NPort6650-8-HV-T
NPort6650-8-T
PowerCords
PWC-C13AU-3B-183PowercordwithAustralian(AU)plug,1.83m
ApplicableModels:
NPort6610-16-48V
NPort6650-8-48V
NPort6650-16-HV-T
NPort6610-8-48V
NPort6610-32
NPort6650-8
NPort6650-32
NPort6610-32-48V
NPort6610-8
NPort6650-8-T
NPort6610-16
NPort6650-16-48V
NPort6650-8-HV-T
NPort6650-32-48V
NPort6650-32-HV-T
NPort6650-16
NPort6650-16-T
PWC-C13CN-3B-183Powercordwiththree-prongChina(CN)plug,1.83m
ApplicableModels:
NPort6650-32
NPort6650-8-T
NPort6650-8-48V
NPort6650-16
NPort6650-16-48V
NPort6650-16-T
NPort6610-32
10
NPort6650-8-HV-T
NPort6610-16
NPort6650-8
NPort6610-32-48V
NPort6650-16-HV-T
NPort6610-16-48V
NPort6610-8-48V
NPort6650-32-48V
NPort6610-8
NPort6650-32-HV-T
PWC-C13EU-3B-183PowercordwithContinentalEurope(EU)plug,1.83m
ApplicableModels:
NPort6650-8-48V
NPort6650-8-HV-T
NPort6650-32
NPort6650-16
NPort6650-16-T
NPort6650-16-HV-T
NPort6610-32
NPort6650-16-48V
NPort6610-16-48V
NPort6610-8
NPort6610-8-48V
NPort6650-32-48V
NPort6650-32-HV-T
NPort6650-8
NPort6610-16
NPort6610-32-48V
NPort6650-8-T
PWC-C13JP-3B-183PowercordwithJapan(JP)plug,7A/125V,1.83m
ApplicableModels:
NPort6650-16-T
NPort6650-8
NPort6610-8
NPort6650-8-HV-T
NPort6650-32
NPort6610-8-48V
NPort6650-8-T
NPort6650-16
NPort6610-16-48V
NPort6610-32-48V
NPort6650-16-HV-T
NPort6650-8-48V
NPort6610-16
NPort6650-16-48V
NPort6610-32
NPort6650-32-48V
NPort6650-32-HV-T
PWC-C13UK-3B-183PowercordwithUnitedKingdom(UK)plug,1.83m
ApplicableModels:
NPort6650-16-HV-T
NPort6650-16
NPort6610-32
NPort6610-16
NPort6610-8-48V
NPort6650-16-T
NPort6610-8
NPort6610-32-48V
NPort6650-8
NPort6650-8-T
NPort6650-16-48V
NPort6650-32
NPort6650-32-HV-T
NPort6650-8-48V
NPort6650-32-48V
NPort6650-8-HV-T
NPort6610-16-48V
PWC-C13US-3B-183PowercordwithUnitedStates(US)plug,1.83m
ApplicableModels:
11
NPort6650-32
NPort6650-8
NPort6650-16
NPort6610-8
NPort6650-8-HV-T
NPort6610-32
NPort6610-8-48V
NPort6610-16
NPort6610-16-48V
NPort6650-16-48V
NPort6650-8-48V
NPort6650-8-T
NPort6610-32-48V
NPort6650-32-48V
NPort6650-32-HV-T
NPort6650-16-HV-T
NPort6650-16-T
PWC-C7AU-2B-183PowercordwithAustralian(AU)plug,2.5A/250V,1.83m
ApplicableModels:
NPort6450-T
NPort6450
PWC-C7EU-2B-183PowercordwithContinentalEurope(EU)plug,2.5A/250V,1.83m
ApplicableModels:
NPort6450
NPort6450-T
PWC-C7JP-2B-183Powercordfordesktop-typepoweradapterswithJapan(JP)plug,7A/125V,1.83m
ApplicableModels:
NPort6450-T
NPort6450
PWC-C7UK-2B-183PowercordwithUnitedKingdom(UK)plug,2.5A/250V,1.83m
ApplicableModels:
NPort6450-T
NPort6450
PWC-C7US-2B-183PowercordwithUnitedStates(US)plug,10A/125V,1.83m
ApplicableModels:
NPort6450
NPort6450-T
CBL-PJ21NOPEN-BK-30Lockingbarrelplugtobare-wirecable
Wall-MountingKits
WK-35-01Wall-mountingkitwith2plates(35x44x2.5mm)and6screws
ApplicableModels:
NPort6450
NPort6450-T
12
Rack-MountingKits
WK-44-01Rack-mountingkit,2L-shapedplates,8screws,44x57.5x1.6mm
ApplicableModels:
NPort6610-8
NPort6610-32
NPort6610-32-48V
NPort6610-16-48V
NPort6610-16
NPort6610-8-48V
NPort6650-16-T
NPort6650-16-48V
NPort6650-16
NPort6650-32-HV-T
NPort6650-16-HV-T
NPort6650-8-T
NPort6650-32
NPort6650-32-48V
NPort6650-8-HV-T
NPort6650-8
NPort6650-8-48V
©dAug11,2021.
Thisdocumentandanyportionthereofmaynotbereproducedorusedinanymannerwhatsoeverwithouttheexpresswrittenpermissionof
urwebsiteforthemostup-to-dateproductinformation.
13
2024年9月11日发(作者:羊舌宵月)
NPort6400/6600Series
4/8/16/32-portRS-232/422/485secureterminalservers
FeaturesandBenefits
•
LCDpanelforeasyIPaddressconfiguration()
•
SecureoperationmodesforRealCOM,TCPServer,TCPClient,Pair
Connection,Terminal,andReverseTerminal
•
Nonstandardbaudratessupportedwithhighprecision
•
PortbuffersforstoringserialdatawhentheEthernetisoffline
•
SupportsIPv6
•
Ethernetredundancy(STP/RSTP/TurboRing)withnetworkmodule
•
GenericserialcommandssupportedinCommand-by-Commandmode
•
SecurityfeaturesbasedonIEC62443
Certifications
Introduction
TheNPort®6000isaterminalserverthatuse32serialdevices
ofanytypecanbeconnectedtotheNPort®6000,ernetportcanbeconfiguredforanormalorsecureTCP/IP
rt®6000securedeviceserversaretherightchoiceforapplicationsthatuselargenumbersofserialdevicespackedintoa
tybreachesareintolerableandtheNPort®6000SeriesensuresdatatransmissionintegritywithsupportforDES,3DES,and
devicesofanytypecanbeconnectedtotheNPort®6000,andeachserialportontheNPort®6000canbe
configuredindependentlyforRS-232,RS-422,orRS-485transmission.
NoDataLossIfEthernetConnectionFails
TheNPort®6000isareliabledeviceserverthatprovidesuserswithsecureserial-to-Ethernetdatatransmissionandacustomer-orientedhardware
thernetconnectionfails,theNPort®eEthernetconnectionis
re-established,theNPort®6000willanincreasetheportbuffer
sizebyinstallinganSDcard.
LCDPanelMakesConfigurationEasy
TheNPort®el
displaystheservername,serialnumber,andIPaddress,andanyof
thedeviceserver’sconfigurationparameters,suchasIPaddress,
netmask,andgatewayaddress,canbeupdatedeasilyandquickly.
Note:TheLCDpanelisonlyavailablewithstandard-temperature
models.
AdjustableResistorValuesforRS-485Communication
TheNPort®6600providesadjustabletermination,pullhigh,andpull
critical
environments,terminationresistorsmaybeneededtopreventthe
reflectionofserialsignals,andthepullhighandpulllowresistorsmay
nosetofresistorvaluesworksforeveryenvironment,theNPort®
6600allowsmanualadjustmentoftheresistorvaluesforeachserial
portusingbuilt-inDIPswitches.
1
Specifications
Memory
SDSlotUpto32GB(SD2.0compatible)
Input/OutputInterface
AlarmContactChannelsResistiveload:1A@24VDC
EthernetInterface
10/100BaseT(X)Ports(RJ45connector)1
AutoMDI/MDI-Xconnection
1.5kV(built-in)
NMSeriesexpansionmodulesforoptionalextensionofRJ45andfiberEthernetports
800
TypicalDistance
Typical(nm)
WavelengthTXRange(nm)
RXRange(nm)
TXRange(dBm)
RXRange(dBm)
OpticalPower
LinkBudget(dB)
DispersionPenalty
(dB)
4km
1300
1260to1360
1100to1600
-10to-20
-3to-32
12
3
5km40km
1310
1280to1340
1100to1600
0to-5
-3to-34
29
1
MagneticIsolationProtection
CompatibleModules
OpticalFiber
Note:Whenconnectingasingle-modefibertransceiver,werecommendusingan
attenuatortopreventdamagecausedbyexcessiveopticalpower.
Note:Computethe“typicaldistance”ofaspecificfibertransceiverasfollows:Link
budget(dB)>dispersionpenalty(dB)+totallinkloss(dB).
EthernetSoftwareFeatures
ConfigurationOptionsWebConsole(HTTP/HTTPS),WindowsUtility,DeviceSearchUtility(DSU),MCCTool,
SerialConsole,Telnet/SSHConsole
ARP,BOOTP,DHCPClient,DNS,HTTP,ICMP,IPv4/IPv6,PPPOE,SMTP,SNMPv1/v2c/
v3,SNTP,TCP/IP,Telnet,UDP
Windows95/98/ME/NT/2000,WindowsXP/2003/Vista/2008/7/8/8.1/10(x86/x64),
Windows2008R2/2012/2012R2/2016/2019(x64),WindowsEmbeddedCE5.0/6.0,
WindowsXPEmbedded
Kernelversions:2.4.x,2.6.x,3.x,4.x,and5.x
SCOUNIX,SCOOpenServer,UnixWare7,QNX4.25,QNX6.x,Solaris10,FreeBSD,AIX
5.x,HP-UX11i,MacOSX,macOS10.12,macOS10.13,macOS10.14,macOS10.15
ter
MIB-II
SNTPClient
Management
WindowsRealCOMDrivers
LinuxRealTTYDrivers
FixedTTYDrivers
AndroidAPI
MIB
TimeManagement
2
UnicastRouting
Authentication
RIPV1/V2,StaticRoute
LocalAccountAccessibility,RADIUS,TACACS+
SerialInterface
ConnectorNPort6600Models:8-pinRJ45
NPort6450Models:DB9male
NPort6450Models:4
NPort6600-8Models:8
NPort6600-16Models:16
NPort6600-32Models:32
NPort6610Models:RS-232
NPort6450/6650Models:RS-232/422/485
ReverseSSH,SecurePairConnection,SecureRealCOM,SecureTCPClient,Secure
TCPServer,SSH
Disabled,EthernetModem,PairConnection,PPP,Printer,RealCOM,ReverseTelnet,
RFC2217,TCPClient,TCPServer,Terminal,UDP
50bpsto921.6kbps(supportsnon-standardbaudrates)
NPort6600Models:RS-232(TxD,RxD,GND),8-pinRJ45(19200,n,8,1)
5,6,7,8
1,1.5,2
None,Even,Odd,Space,Mark
RTS/CTS,DTR/DSR,XON/XOFF
NPort6450/6650Models:1kilo-ohm,150kilo-ohms
NPort6450/6650Models:supportADDC®(automaticdatadirectioncontrol)
NPort6450/6650Models:120ohms
s
SerialStandards
SecureOperationModes
StandardOperationModes
Baudrate
ConsolePort
DataBits
StopBits
Parity
FlowControl
PullHigh/LowResistorforRS-485
RS-485DataDirectionControl
TerminatorforRS-485
SerialSignals
RS-232
RS-422
RS-485-4w
RS-485-2w
TxD,RxD,RTS,CTS,DTR,DSR,DCD,GND
Tx+,Tx-,Rx+,Rx-,GND
Tx+,Tx-,Rx+,Rx-,GND
Data+,Data-,GND
PowerParameters
InputCurrentNPort6450Models:730mA@12VDC
NPort6600Models:
DCModels:293mA@48VDC,200mA@88VDC
ACModels:140mA@100VAC(8ports),192mA@100VAC(16ports),285mA@100
VAC(32ports)
InputVoltageNPort6450Models:12to48VDC
NPort6600Models:
ACModels:100to240VAC
DC-48VModels:±48VDC(20to72VDC,-20to-72VDC)
DC-HVModels:110VDC(88to300VDC)
3
Reliability
AutomaticRebootTrigger
AlertTools
Built-inWDT
Built-inbuzzerandRTC(real-timeclock)
PhysicalCharacteristics
Housing
Dimensions(withears)
Metal
NPort6450Models:181x103x35mm(7.13x4.06x1.38in)
NPort6600Models:480x195x44mm(18.9x7.68x1.73in)
NPort6450Models:158x103x35mm(6.22x4.06x1.38in)
NPort6600Models:440x195x44mm(17.32x7.68x1.73in)
NPort6450Models:1,020g(2.25lb)
NPort6600-8Models:3,460g(7.63lb)
NPort6600-16Models:3,580g(7.89lb)
NPort6600-32Models:3,600g(7.94lb)
LCDpaneldisplay(non-Tmodelsonly)
Pushbuttonsforconfiguration(non-Tmodelsonly)
NPort6450Models:Desktop,DIN-railmounting,Wallmounting
NPort6600Models:Rackmounting(withoptionalkit)
Dimensions(withoutears)
Weight
InteractiveInterface
Installation
EnvironmentalLimits
OperatingTemperatureStandardModels:0to55°C(32to131°F)
-HVModels:-40to85°C(-40to185°F)
Allother-TModels:-40to75°C(-40to167°F)
StandardModels:-40to75°C(-40to167°F)
-HVModels:-40to85°C(-40to185°F)
Allother-TModels:-40to75°C(-40to167°F)
5to95%(non-condensing)
StorageTemperature(packageincluded)
AmbientRelativeHumidity
StandardsandCertifications
EMC
EMI
EMS
EN55032/24
CISPR32,FCCPart15BClassA
NPort6450Models:
IEC61000-4-2ESD:Contact:4kV;Air:8kV
IEC61000-4-3RS:80MHzto1GHz:3V/m
IEC61000-4-4EFT:Power:1kV;Signal:0.5kV
IEC61000-4-5Surge:Power:1kV
IEC61000-4-6CS:150kHzto80MHz:3V/m;Signal:3V/m
IEC61000-4-8PFMF
IEC61000-4-11
NPort6600Models(except-48V/-HVmodels):
IEC61000-4-2ESD:Contact:4kV;Air:8kV
IEC61000-4-3RS:80MHzto1GHz:3V/m
IEC61000-4-4EFT:Power1kV;Signal0.5kV
IEC61000-4-5Surge:Power:2kV
IEC61000-4-6CS:150kHzto80MHz:3V/m;Signal:3V/m
IEC61000-4-8PFMF
IEC61000-4-11
NPort6600-48VModels:
IEC61000-4-2ESD:Contact:4kV;Air:8kV
IEC61000-4-3RS:80MHzto1GHz:3V/m
IEC61000-4-4EFT:Power:1kV;Signal:0.5kV
IEC61000-4-5Surge:Power:1kV
IEC61000-4-6CS:150kHzto80MHz:3V/m;Signal:3V/m
IEC61000-4-8PFMF
NPort6650-HVModels:
IEC61000-4-2ESD:Contact:4kV;Air:8kV
4
IEC61000-4-3RS:80MHzto1GHz:3V/m
IEC61000-4-4EFT:Power:4kV;Signal:2kV
IEC61000-4-5Surge:Power:2kV
IEC61000-4-6CS:150kHzto80MHz:3V/m;Signal:3V/m
IEC61000-4-8PFMF
Safety
TrafficControl
Vibration
Freefall
UL60950-1
NEMATS2
IEC60068-2-6
IEC60068-2-34
Declaration
GreenProductRoHS,CRoHS,WEEE
MTBF
TimeNPort6450Models:850,905hrs
NPort6610-8Models:135,891hrs
NPort6610-16Models:102,373hrs
NPort6610-32Models:68,707hrs
NPort6650-8Models:636,600hrs
NPort6650-16Models:439,673hrs
NPort6650-32Models:310,078hrs
NPort6650-8-HV-T:501,171hrs
NPort6650-16-HV-T:380,006hrs
NPort6650-32-HV-T:290,914hrs
NPort6450Models:Telcordia(Bellcore)StandardTR/SR
NPort6600Models:Telcordia(Bellcore)Standard
Standards
Warranty
WarrantyPeriod
Details
5years
/warranty
PackageContents
Device
InstallationKit
Cable
PowerSupply
1xNPort6400/6600Seriesterminalserver
2xrack-mountingear(NPort6600models)
1xDB9maletoRJ458-pin(NPort6600models)
1xpowercable,suitableforyourregion(ACmodelsexcept-Tmodels)
1xpoweradapter,suitableforyourregion(NPort6450)
1xquickinstallationguide
1xwarrantycard
Documentation
5
Dimensions
NPort6450NPort6600
OrderingInformation
ModelName
NPort6450
NPort6450-T
NPort6610-8
NPort6610-8-48V
NPort6610-16
NPort6610-16-48V
NPort6610-32
NPort6610-32-48V
NPort6650-8
NPort6650-8-T
NPort6650-8-HV-T
alPorts
4
4
8
8
16
16
32
32
8
8
8
SerialStandards
RS-232/422/485
RS-232/422/485
RS-232
RS-232
RS-232
RS-232
RS-232
RS-232
RS-232/422/485
RS-232/422/485
RS-232/422/485
SerialInterface
DB9male
DB9male
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
OperatingTemp.
0to55°C
-40to75°C
0to55°C
0to55°C
0to55°C
0to55°C
0to55°C
0to55°C
0to55°C
-40to75°C
-40to85°C
InputVoltage
12to48VDC
12to48VDC
100-240VAC
48VDC;+20to+72
VDC,-20to-72VDC
100-240VAC
48VDC;+20to+72
VDC,-20to-72VDC
100-240VAC
48VDC;+20to+72
VDC,-20to-72VDC
100-240VAC
100-240VAC
110VDC;88to300
VDC
48VDC;+20to+72
VDC,-20to-72VDC
100-240VAC
48VDC;+20to+72
VDC,-20to-72VDC
100-240VAC
110VDC;88to300
VDC
100-240VAC
NPort6650-8-48V
NPort6650-16
NPort6650-16-48V
NPort6650-16-T
NPort6650-16-HV-T
NPort6650-32
8
16
16
16
16
32
RS-232/422/485
RS-232/422/485
RS-232/422/485
RS-232/422/485
RS-232/422/485
RS-232/422/485
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
8-pinRJ45
0to55°C
0to55°C
0to55°C
-40to75°C
-40to85°C
0to55°C
6
NPort6650-32-48V32RS-232/422/4858-pinRJ450to55°C
48VDC;+20to+72
VDC,-20to-72VDC
110VDC;88to300
VDC
NPort6650-32-HV-T32RS-232/422/4858-pinRJ45-40to85°C
Accessories(soldseparately)
Cables
CBL-RJ45F25-1508-pinRJ45toDB25femaleserialcable,1.5m
ApplicableModels:
NPort6650-8-48V
NPort6650-8-HV-T
NPort6650-32-48V
NPort6650-32-HV-T
NPort6650-16-HV-T
NPort6650-16-48V
CBL-RJ45F9-1508-pinRJ45toDB9femaleserialcable,1.5m
ApplicableModels:
NPort6650-16
NPort6650-8-48V
NPort6610-32-48V
NPort6650-16-48V
NPort6650-16-T
NPort6650-8
NPort6650-8-HV-T
NPort6610-16
NPort6650-32-HV-T
NPort6610-8
NPort6650-32-48V
NPort6650-16-HV-T
NPort6610-32
NPort6610-16-48V
NPort6610-8-48V
NPort6650-8-T
NPort6650-32
CBL-RJ45M25-1508-pinRJ45toDB25maleserialcable,1.5m
ApplicableModels:
NPort6650-8
NPort6650-8-HV-T
NPort6610-16
NPort6650-8-T
NPort6610-32-48V
NPort6650-16-T
NPort6650-8-48V
NPort6650-16-HV-T
NPort6650-16-48V
NPort6650-16
NPort6650-32-HV-T
NPort6650-32
NPort6610-8
NPort6610-8-48V
NPort6650-32-48V
NPort6610-16-48V
NPort6610-32
CBL-RJ45M9-1508-pinRJ45toDB9maleserialcable,1.5m
ApplicableModels:
NPort6610-32-48V
NPort6610-8-48V
NPort6650-32
NPort6650-8
NPort6650-32-HV-T
NPort6610-16
NPort6610-8
NPort6650-8-48V
7
NPort6650-16
NPort6650-16-HV-T
NPort6610-16-48V
NPort6610-32
NPort6650-32-48V
NPort6650-8-T
NPort6650-16-T
NPort6650-8-HV-T
NPort6650-16-48V
CBL-RJ45SF25-1508-pinRJ45toDB25femaleserialcablewithshielding,1.5m
ApplicableModels:
NPort6610-16
NPort6610-32-48V
NPort6610-32
NPort6650-32
NPort6650-32-48V
NPort6610-8
NPort6650-16-T
NPort6610-16-48V
NPort6650-32-HV-T
NPort6650-16
NPort6650-8
NPort6650-16-48V
NPort6650-16-HV-T
NPort6650-8-T
NPort6610-8-48V
NPort6650-8-48V
NPort6650-8-HV-T
CBL-RJ45SF9-1508-pinRJ45toDB9femaleserialcablewithshielding,1.5m
ApplicableModels:
NPort6610-32
NPort6650-8
NPort6650-32
NPort6650-8-HV-T
NPort6650-16-HV-T
NPort6610-8
NPort6650-16
NPort6610-16
NPort6650-16-48V
NPort6650-8-T
NPort6650-8-48V
NPort6650-32-48V
NPort6650-16-T
NPort6610-32-48V
NPort6610-8-48V
NPort6610-16-48V
NPort6650-32-HV-T
CBL-RJ45SM25-1508-pinRJ45toDB25maleserialcablewithshielding,1.5m
ApplicableModels:
NPort6650-8
NPort6650-8-48V
NPort6610-32-48V
NPort6650-8-T
NPort6650-32-HV-T
NPort6650-32
NPort6610-16
NPort6650-16
NPort6610-8-48V
NPort6650-16-T
NPort6610-8
NPort6610-16-48V
NPort6650-16-48V
NPort6610-32
NPort6650-8-HV-T
NPort6650-32-48V
NPort6650-16-HV-T
CBL-RJ45SM9-1508-pinRJ45toDB9maleserialcablewithshielding,1.5m
ApplicableModels:
NPort6610-16
8
NPort6650-32
NPort6650-8-T
NPort6610-32-48V
NPort6610-16-48V
NPort6650-16-48V
NPort6610-8
NPort6650-32-HV-T
NPort6610-8-48V
NPort6650-16-HV-T
NPort6650-32-48V
NPort6650-8-HV-T
NPort6650-16-T
NPort6610-32
NPort6650-8-48V
NPort6650-16
NPort6650-8
Connectors
MiniDB9F-to-TBDB9femaletoterminalblockconnector
ApplicableModels:
NPort6450
NPort6450-T
DIN-RailMountingKits
DK35ADIN-railmountingkit,35mm
ApplicableModels:
NPort6450
NPort6450-T
ExpansionModules
NM-TX01
NM-TX01-T
NM-TX02
NM-TX02-T
NM-FX01-M-SC
NM-FX01-M-SC-T
NM-FX01-S-SC
NM-FX01-S-SC-T
NM-FX02-M-SC
NM-FX02-M-SC-T
NM-FX02-S-SC
NM-FX02-S-SC-T
110/100BaseTXport
110/100BaseTXport,-40to75°Coperatingtemperature
210/100BaseTXports
210/100BaseTXports,-40to75°Coperatingtemperature
1100BaseFXport,multi-mode,SCconnector
1100BaseFXport,multi-mode,SCconnector,-40to75°Coperatingtemperature
1100BaseFXport,single-mode,SCconnector
1100BaseFXport,single-mode,SCconnector,-40to75°Coperatingtemperature
2100BaseFXports,multi-mode,SCconnector
2100BaseFXports,multi-mode,SCconnector,-40to75°Coperatingtemperature
2100BaseFXports,single-mode,SCconnector
2100BaseFXports,single-mode,SCconnector,-40to75°Coperatingtemperature
PowerAdapters
PWR-12125-DT-S2Desktoppowersupply(requirespowercord),12VDC,1.25A,100to240VAC,0to40°Coperating
temperature
ApplicableModels:
NPort6450
NPort6450-T
PWR-12150-AU-SA-TLockingbarrelplug,12VDC,1.5A,100to240VAC,Australia(AU)plug,-40to75°Coperating
temperature
ApplicableModels:
NPort6450-T
NPort6650-16-HV-T
NPort6650-16-T
NPort6650-32-HV-T
NPort6650-8-HV-T
NPort6650-8-T
9
PWR-12150-CN-SA-TLockingbarrelplug,12VDC,1.5A,100to240VAC,China(CN)plug,-40to75°Coperating
temperature
ApplicableModels:
NPort6450-T
NPort6650-16-HV-T
NPort6650-16-T
NPort6650-32-HV-T
NPort6650-8-HV-T
NPort6650-8-T
PWR-12150-EU-SA-TLockingbarrelplug,12VDC,1.5A,100to240VAC,ContinentalEurope(EU)plug,-40to75°C
operatingtemperature
ApplicableModels:
NPort6450-T
NPort6650-16-HV-T
NPort6650-16-T
NPort6650-32-HV-T
NPort6650-8-HV-T
NPort6650-8-T
PWR-12150-UK-SA-TLockingbarrelplug,12VDC,1.5A,100to240VAC,UnitedKingdom(UK)plug,-40to75°Coperating
temperature
ApplicableModels:
NPort6450-T
NPort6650-16-HV-T
NPort6650-16-T
NPort6650-32-HV-T
NPort6650-8-HV-T
NPort6650-8-T
PWR-12150-USJP-SA-TLockingbarrelplug,12VDC1.5A,100to240VAC,UnitedStates/Japan(US/JP)plug,-40to75°C
operatingtemperature
ApplicableModels:
NPort6450-T
NPort6650-16-HV-T
NPort6650-16-T
NPort6650-32-HV-T
NPort6650-8-HV-T
NPort6650-8-T
PowerCords
PWC-C13AU-3B-183PowercordwithAustralian(AU)plug,1.83m
ApplicableModels:
NPort6610-16-48V
NPort6650-8-48V
NPort6650-16-HV-T
NPort6610-8-48V
NPort6610-32
NPort6650-8
NPort6650-32
NPort6610-32-48V
NPort6610-8
NPort6650-8-T
NPort6610-16
NPort6650-16-48V
NPort6650-8-HV-T
NPort6650-32-48V
NPort6650-32-HV-T
NPort6650-16
NPort6650-16-T
PWC-C13CN-3B-183Powercordwiththree-prongChina(CN)plug,1.83m
ApplicableModels:
NPort6650-32
NPort6650-8-T
NPort6650-8-48V
NPort6650-16
NPort6650-16-48V
NPort6650-16-T
NPort6610-32
10
NPort6650-8-HV-T
NPort6610-16
NPort6650-8
NPort6610-32-48V
NPort6650-16-HV-T
NPort6610-16-48V
NPort6610-8-48V
NPort6650-32-48V
NPort6610-8
NPort6650-32-HV-T
PWC-C13EU-3B-183PowercordwithContinentalEurope(EU)plug,1.83m
ApplicableModels:
NPort6650-8-48V
NPort6650-8-HV-T
NPort6650-32
NPort6650-16
NPort6650-16-T
NPort6650-16-HV-T
NPort6610-32
NPort6650-16-48V
NPort6610-16-48V
NPort6610-8
NPort6610-8-48V
NPort6650-32-48V
NPort6650-32-HV-T
NPort6650-8
NPort6610-16
NPort6610-32-48V
NPort6650-8-T
PWC-C13JP-3B-183PowercordwithJapan(JP)plug,7A/125V,1.83m
ApplicableModels:
NPort6650-16-T
NPort6650-8
NPort6610-8
NPort6650-8-HV-T
NPort6650-32
NPort6610-8-48V
NPort6650-8-T
NPort6650-16
NPort6610-16-48V
NPort6610-32-48V
NPort6650-16-HV-T
NPort6650-8-48V
NPort6610-16
NPort6650-16-48V
NPort6610-32
NPort6650-32-48V
NPort6650-32-HV-T
PWC-C13UK-3B-183PowercordwithUnitedKingdom(UK)plug,1.83m
ApplicableModels:
NPort6650-16-HV-T
NPort6650-16
NPort6610-32
NPort6610-16
NPort6610-8-48V
NPort6650-16-T
NPort6610-8
NPort6610-32-48V
NPort6650-8
NPort6650-8-T
NPort6650-16-48V
NPort6650-32
NPort6650-32-HV-T
NPort6650-8-48V
NPort6650-32-48V
NPort6650-8-HV-T
NPort6610-16-48V
PWC-C13US-3B-183PowercordwithUnitedStates(US)plug,1.83m
ApplicableModels:
11
NPort6650-32
NPort6650-8
NPort6650-16
NPort6610-8
NPort6650-8-HV-T
NPort6610-32
NPort6610-8-48V
NPort6610-16
NPort6610-16-48V
NPort6650-16-48V
NPort6650-8-48V
NPort6650-8-T
NPort6610-32-48V
NPort6650-32-48V
NPort6650-32-HV-T
NPort6650-16-HV-T
NPort6650-16-T
PWC-C7AU-2B-183PowercordwithAustralian(AU)plug,2.5A/250V,1.83m
ApplicableModels:
NPort6450-T
NPort6450
PWC-C7EU-2B-183PowercordwithContinentalEurope(EU)plug,2.5A/250V,1.83m
ApplicableModels:
NPort6450
NPort6450-T
PWC-C7JP-2B-183Powercordfordesktop-typepoweradapterswithJapan(JP)plug,7A/125V,1.83m
ApplicableModels:
NPort6450-T
NPort6450
PWC-C7UK-2B-183PowercordwithUnitedKingdom(UK)plug,2.5A/250V,1.83m
ApplicableModels:
NPort6450-T
NPort6450
PWC-C7US-2B-183PowercordwithUnitedStates(US)plug,10A/125V,1.83m
ApplicableModels:
NPort6450
NPort6450-T
CBL-PJ21NOPEN-BK-30Lockingbarrelplugtobare-wirecable
Wall-MountingKits
WK-35-01Wall-mountingkitwith2plates(35x44x2.5mm)and6screws
ApplicableModels:
NPort6450
NPort6450-T
12
Rack-MountingKits
WK-44-01Rack-mountingkit,2L-shapedplates,8screws,44x57.5x1.6mm
ApplicableModels:
NPort6610-8
NPort6610-32
NPort6610-32-48V
NPort6610-16-48V
NPort6610-16
NPort6610-8-48V
NPort6650-16-T
NPort6650-16-48V
NPort6650-16
NPort6650-32-HV-T
NPort6650-16-HV-T
NPort6650-8-T
NPort6650-32
NPort6650-32-48V
NPort6650-8-HV-T
NPort6650-8
NPort6650-8-48V
©dAug11,2021.
Thisdocumentandanyportionthereofmaynotbereproducedorusedinanymannerwhatsoeverwithouttheexpresswrittenpermissionof
urwebsiteforthemostup-to-dateproductinformation.
13